Epson WF C869RA,C869RE Service Repair Manuals Page 401-450

EPSON WF-C869Ra/WF-C869R Revision E Repair Work Repair Work 401 Confidential Cover Open Sensor (BK) 1. Remove one screw (S9: ). 2. Disengage the hook, then remove the Cover Open Sensor (BK). D1 Cover Open Sensor (BK) Hook No. S9 Screw Type C.B.P-TITE-SCREW-3x10-F.ZN-3C (Black) Open Sensor (BK) The length of the two hooks on mechanical contact sensor differs. See the following and make sure to release the shorter hook first when removing the mechanical contact sensor. 1. Disengage the hook by pushing up the open sensor (BK). 2. Remove the cable from the connector of the open sensor (BK). D2 Hook (long) Hook (short) Mechanical Contact Sensor Open Sensor (BK) Connector Cable